HSC §9635: (a) All individual crypt openings shall be sealed with a solid panel of precast concrete, not less than 1 1 2 inches thick, fiber reinforced cement board not less than 7 16 inch thick, or other incomb
Read the full statutory text
(a) All individual crypt openings shall be sealed with a solid panel of precast concrete, not less than 1 1 2 inches thick, fiber reinforced cement board not less than 7 16 inch thick, or other incombustible material that meets all of the following requirements: (1) A minimum density of 80 pounds per cubic foot. (2) A minimum modulus of rupture of 270 pounds per square inch. (3) A minimum compressive strength of 2500 pounds per square inch. (4) A rating that conforms to Underwriters Laboratories fire hazard class 1. (b) All panels shall be securely set in with a high quality, nonflammable, resilient, and nonhardening urethane, silicone base, or other appropriate sealant for permanent sealing after interment is made in the crypt. Seal panels shall be set independent of crypt fronts.
Verify at the official source: California legislative text
Facing this? Know exactly what happens next.
MOFRD turns this code section into your situation: the deadlines that apply to you, the forms your county uses, and the resolution paths people in your position actually take. Free for 3 days — no card required.
This page is legal information, not legal advice. Code text is sourced from official publications and may lag amendments — always confirm at the official source linked above. Plain-English summaries and relationship data are AI-derived and reviewed on an ongoing basis; verify with a licensed attorney before acting.